LUMIS 100 VPAPS
- BrandsResmed
- Product Code:LUMIS 100 VPAPS
- Availability:In Stock
- M.R.P:
₹80,300
-
Sale price:
₹56,000
(30% OFF)
Warranty Service Type: Manufacturer’s Service Center
Lumis 100 VPAP S is a noninvasive ventilator
designed for spontaneously breathing, non-dependent patients with respiratory
insufficiency.
The ventilator is easy to set up and use, and is supported by ResMed’s ResScan™ patient management software.
Key features
IntelligentAir is a collection of ResMed technologies that
can tailor therapy to individual breathing needs:
·
Vsync provides excellent
patient–ventilator synchrony, even in the presence of significant leak.
·
TiControl™ lets you set min and max limits
on either side of the patient’s ideal inspiratory time to encourage spontaneous
breath.
·
Trigger and cycle helps you optimise
settings according to the patient’s condition, using five trigger and cycle
sensitivity levels.
·
QuickNav for low-touch therapy adjustment.
By simply double-clicking the home button on the device, you can toggle between
the Settings and Monitoring screens to change and check settings quickly and
easily.
·
Climate Control Auto for automatic
humidification. When used with a HumidAir™ heated humidifier and
ClimateLineAir™ heated tube, Lumis delivers humidification automatically – no
settings to change and no complicated menus to navigate.
·
Ramp and Ramp Down for extra comfort. Lumis
offers both Ramp and Ramp Down features to help patients ease into and out of
each therapy session.
·
Modes – CPAP, S
·
Operating pressure range – 2–25 cm H2O (2–25
hPa) in S mode 4–20 cm H2O (4–20 hPa) in CPAP mode
·
Sound pressure level – 26.6 dBA with
uncertainty of 2 dBA as measured according to ISO 17510-1:2009 (CPAP mode)
·
Dimensions (H x W x D) – 116 mm x 255 mm x 150
mm (Device with HumidAir humidifier)
·
Weight (Device with HumidAir humidifier) – 1268
gm
·
Power Supply – 90W power supply unit Input
range: 100–240V, 50–60Hz, 57VA (typical power consumption) 108VA (peak power
consumption)
·
Operating temperature/ humidity/altitude – +5°C
to +35°C/ 10–95% relative humidity, non-condensing/ Sea level to 2,591 m; air
pressure range 1013 hPa to 738 hPa
·
Storage and transport temperature/humidity –
-20°C to +60°C/ 5–95% relative humidity, non-condensing
·
Housing construction – Flame retardant
engineering thermoplastic
·
Supplemental oxygen – Recommended maximum flow:
15 L/min (CPAP, S)
·
Standard air filter – Polyester non-woven fibre
·
Tubing – SlimLine™ and ClimateLineAir (15 mm);
Standard (19 mm)
·
Air outlet – 22 mm air outlet complies with ISO
5356-1:2004
·
Electromagnetic compatibility – Requirements
(EMC) according to IEC60601-1-2:2007 for residential, commercial, and light
industry environments
·
Aircraft use – ResMed confirms that device
meets the Federal Aviation Administration (FAA) requirements (RTCA/DO-160,
section 21, category M) for all phases of air travel
·
IEC 60601-1: 2006 classification – Class II
(double insulation), Type BF Ingress protection IP22